Differential Pressure Control Valves – also commonly called DPCVs – are installed in heating or cooling systems to control sub-circuit pressure to a set or given maximum. They offer a flexible range meeting any system demand.

How does a DPCV valve work?

The DPCV contains a diaphragm that separates two chambers in the valve; in this example, one chamber is connected (internally) to the valve inlet and the other, via a capillary tube, to a tapping in the double-regulating valve in the flow pipework.

What is a differential bypass valve?

The differential bypass valve is used in systems where heating loads may be excluded from the circuit as zone valves close. It controls the excess flow in the system by acting as a bypass while ensuring adequate flow to the remaining open circuits.

What is a differential pressure?

Differential pressure is essentially the difference in pressure between two given points. It is a type of pressure measured within different industries using differential pressure sensors. Absolute pressure is the combined pressure of the atmosphere and the measured point.

How does a differential bypass valve work?

What is the difference between on off control and modulating control?

A less common ON/OFF control is where there is only one digital output (DO-1). This is referred to as TWO POSITION control. This type of control is used with failsafe actuators. In modulating/proportional control, the output to the actuator varies continuously and is not limited to being fully open or fully closed.

What is a modulating control valve CDL?

What does a modulating control valve do? It enables you to put on the spring brakes gradually. It enables you to switch from the air braking system to the spring brake system. It enables you to gradually decrease the pressure being sent to the trailer brakes.

Where to mount a differential pressure control valve?

Installation: differential pressure controller should be mounted on return pipe with connection via impulse tube to supply pipe. Branch should be balanced with a differential pressure controller for dynamic hydronic balance, with following characteristics: Valve should have variable Dp setting.

Which is differential pressure controller is used in return pipes?

TA-PILOT-R is a differential pressure controller for use in return pipes. Measuring points enable pressure measurements for diagnostics. The TA-PILOT-R is a high performing differential pressure controller designed to keep a stable differential pressure over the load.

Which is differential pressure control valve does greencon use?

AB-PM differential pressure control valves AB-PM is a combined balancing valve providing both differential pressure control and flow limitation. The valves eliminate pressure fluctuations at full load and partial load conditions and can be equipped with an actuator to allow zone control. GreenCon on/off room thermostats

What kind of valves are used for hydronic balance?

For a proper hydronic balance the valves should be combined with pre-setting valves. AB-PM is a combined balancing valve providing both differential pressure control and flow limitation. The valves eliminate pressure fluctuations at full load and partial load conditions and can be equipped with an actuator to allow zone control.