Completely Self-Protected Transformers (CSP) offer a complete and safe solution against lightning, switch surges and severe overloads.

How does a single-phase distribution transformer work?

A simple single-phase transformer has each winding being wound cylindrically on a soft iron limb separately to provide a necessary magnetic circuit, which is commonly referred to as “transformer core”. It offers a path for the flow of the magnetic field to induce voltage between two windings.

What is single-phase distribution transformer?

Single-phase transformers accept single-phase AC power and output single-phase AC power, typically at a higher or lower voltage level. Energy is transferred from one circuit to one or more circuits via electromagnetic induction.

How does a distribution transformer work?

A distribution transformer or service transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. If mounted on a utility pole, they are called pole-mount transformers.

What is a conventional transformer?

A conventional transformer is a static device which transfers electrical energy from one circuit to another at the same frequency but different voltage. The windings of the conventional transformer are electrically insulated, but magnetically connected. The conventional transformer has two windings.

What is the function of the fuse cutout?

In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads.

What are the parts of a single-phase transformer?

Single phase transformer parts include windings, core, and isolation. The windings should have a low resistance amount, and commonly, they are constructed of copper (hardly ever of aluminum). They are layered around the core and should be isolated from it.

Why is the transformer rated in kVA?

The copper and iron are the two types of losses that occur in the transformer. The copper loss depends on the current (ampere) flows through the windings of the transformer while the iron loss depends on the voltage (volts). i.e., the rating of the transformer is in kVA.

What is X1 and H1 on a transformer?

By convention, terminals Hi and X1 have the same polarity, which means that when H1 is instantaneously positive, X1 is also instantaneously positive. These markings are used in establishing the proper terminal connections when connecting single-phase transformers in parallel, series, or three-phase configurations.

How many wires are in a single phase transformer?

two-wire
Single-phase power is a two-wire alternating current (ac) power circuit. Typically, there is one power wire—the phase wire—and one neutral wire, with current flowing between the power wire (through the load) and the neutral wire.

What are the parts of a CSP transformer?

The primary bushing is labeled “H1” and a grounding nut on the tank is labeled “H2”. This transformer is connected between a phase and neutral. Some of these transformers are CSP (completely self protected). They usually include a primary fuse, a primary arrester, and a secondary breaker with weak-link.

Do you need a Magnex interrupter for CSP Transformers?

With direct connected primary arresters, a MagneX interrupter or a secondary circuit breaker with internal primary voltage fuses, the CSP transformers eliminate the need for separately mounted protective devices while reducing installation costs.

What kind of oil is used in CSP Transformers?

Available from 10-75 kVA (or 10-167 kVA with a MagneX interrupter), CSP transformers meet or exceed the requirements of applicable ANSI and NEMA standards. CSP transformers can be filled with standard electrical grade mineral insulating oil or fire-resistant Envirotemp FR3 fluid.

What kind of transformers are used on poles?

CSP: Pole mounted transformers with one primary bushing are utility type transformers and are the type most commonly used in residential applications. The primary bushing is labeled “H1” and a grounding nut on the tank is labeled “H2”.