What are the wires on a 2-port valve?

A 2-port (or Zone valve) has a permanent 230v supply (usually on the grey wire) plus a Neutral and an Earth wire. There is then also a Motor Live wire (usually the brown) and a Switch Live wire (usually the orange).

How does a Honeywell 2-port valve work?

When the programmer and stat send a Live feed to the 2-port motorised brown wire, the motor drives the valve open to allow water to pass. When the valve is fully open, the end switch closes, allowing electrical current to pass from the grey wire to the orange wire and from there to the boiler Switched Live.

How do Honeywell zone valves work?

Honeywell zone valves offer the flexibility to regulate temperature in a home serviced by a hydronic heating system. When the thermostat calls for heat, the zone valves opens and turns on the water circulating pump to allow water flow to the area.

How does 2 port Motorised valve work?

Two port valves On most types, a spring holds the valve closed. When power is applied, the internal motor opens the valve allowing water to flow. When fully open, a switch inside the valve activates. This switch is normally used to activate the boiler.

How does a 2 port valve work?

Two port valves The simplest type of valve, with two plumbing connections (in and out). On most types, a spring holds the valve closed. When power is applied, the internal motor opens the valve allowing water to flow. When fully open, a switch inside the valve activates.

How many wires does Honeywell 2 port valve have?

However my honeywell 2 port valve has 5 wires and all the wiring diagrams ive seen instruct me for y plan or s plan etc, when I just simply need it to open when current detected and closed when not. Is this possible? many thanks. as it does conventionally and switches on the boiler.

When is the micro switch active on Honeywell 2?

The two port valves wire cores will be most likely be configured in the following way. The micro switch is typically active when the valve is open.

Where do you put the wire for a heat pump?

A heat pump runs your compressor for both heating and cooling. If you don’t know your system type, place this wire into the W terminal. If you have a heat pump system, place it into the O/B terminal. Locate any unconnected wire labeled W or W1.